SIMA: BINDER incubators, drying ovens and climate chambers – sales and service in Poland
Choose equipment by operating temperature
Authorised representative since 1997
- 1997
- authorised BINDER representative and service partner in Poland
- 122
- BINDER models with data sheets
- −90…+300 °C
- operating temperature range of the equipment
- DIN 12880
- mapping at 1, 9 or 27 points and IQ/OQ qualification
BINDER equipment
Choose a category or find equipment by operating temperature.
Incubators standard (heating), cooled and CO2 from −20 to +100 °C
Plant growth chambers for plant cultivation, with LED lighting from −10 to +60 °C
Drying ovens and sterilisers convection and vacuum, also for hot-air sterilisation from ambient +5 to +300 °C
Stability test chambers climate chambers for ICH testing, including photostability, also in walk-in versions from −20 to +100 °C
Climate and test chambers dynamic climate chambers, also with humidity control from −70 to +180 °C
Battery testing chambers with EUCAR safety packages from −70 to +120 °C
Ultra-low temperature freezers UF V ultra-low temperature freezers from −90 to −40 °C
Custom solutions we adapt BINDER equipment to the requirements of a specific test See examples
Select by temperature
All BINDER equipment groups on a single temperature scale. Select a group to see its models and operating range and to request a quote.
Enter a temperature or move the marker along the scale.
“From ambient +5 °C” means 5 °C above room temperature. The scale assumes a room temperature of 20 °C.
Incubation and cultivation

For microbiological incubation and routine cultures at temperatures above ambient. The BD series uses natural convection and is suitable for delicate samples. The BF series has forced air circulation and maintains uniform conditions even when fully loaded.
- Temperature
- BD: from ambient +5 °C to +100 °CBF: from ambient +5–10 °C (depending on model) to +100 °CBD-S: from ambient +5 °C to +70 °CB 28: from +30 to +70 °C
- Models
- B 28; BD 23–720; BD-S 56 and 115; BF 56–720

For incubating and storing samples at temperatures below and above ambient, for example in BOD tests and food testing. The KB ECO and KT are cooled by a Peltier module, so they run quietly and economically.
- Temperature
- KB: from 0 to +70 °CKB PRO: from −20 to +100 °CKB ECO: from 0 to +70 °C (max. 26–28 °C below ambient)KT: from +4 to +100 °C
- Models
- KB 65–1060; KB PRO 130–1600; KB ECO 240–1020; KT 53–170

For cell and tissue cultures. The chamber can be hot-air sterilised at 180 °C, and the CO2 concentration is measured by an infrared sensor. The CBF also actively controls humidity. The CB and CBF 170 and 260 models are also available with oxygen concentration control.
- Temperature
- CB: from ambient +4–5 °C (depending on model) to +50 °CCB-S, CBF and CB with O2 control: from ambient +6 °C to +50 °C
- CO2
- 0–20 %
- Humidity
- CBF: 50–95 %, active steam humidification
- Models
- CB 56, 170, 260; CB-S 170, 260; CBF 170, 260

For plant cultivation and agricultural, physiological and entomological research. LED modules illuminate the plants while the chamber maintains the set temperature. The KBF and KBF PRO also control humidity.
- Temperature
- KBF: from +15 to +50 °CKBF PRO and KB PRO: from −10 to +60 °C
- Humidity
- KBF: 20–50 %KBF PRO: 10–90 %KB PRO: no humidity control
- Models
- KBF, KBF PRO and KB PRO 260, 470, 720, 1060 and 1600
Drying and sterilisation

For drying, hot-air sterilisation, annealing and heat treatment. The ED works with natural convection, the FD and FED with forced convection, the FP allows the temperature profile to be programmed, and the M series is designed for materials testing and ageing tests. The ED-S and FD-S (Solid.Line) are simpler models up to +250 °C.
- Temperature
- ED, FD 23 and FED 400: from ambient +5 °C to +300 °Cother FD, FED and FP: from ambient +10 °C (size 720: +12 °C) to +300 °CM: from ambient +14–23 °C (depending on model) to +300 °CED-S: from ambient +7 °C to +250 °CFD-S: from ambient +10 °C to +250 °CE 28: from +60 to +230 °C
- Models
- E 28; ED 23–720; FD 23–720; FED 56–720; FP 56–720; M 56–720; ED-S and FD-S 56, 115

For gentle drying of temperature-sensitive and solvent-containing materials. The VDL has explosion protection (ATEX) for working with flammable solvents.
- Temperature
- VD: from ambient +9 °C to +220 °CVDL: from ambient +9 °C to +110 °C
- Models
- VD 23, 56, 115; VDL 23, 56, 115
Stability studies and environmental testing

For stability testing of pharmaceuticals according to ICH Q1A (long-term, accelerated and stress testing), as well as of cosmetics and food. The KBF and KBF PRO in sizes 260, 470 and 720 with an ICH light module are also used for photostability testing according to ICH Q1B.
- Temperature
- KBF: from 0 to +70 °CKBF PRO: from −20 to +100 °CKBF-S ECO: from 0 to +70 °C (max. 24–28 °C below ambient)
- Humidity
- KBF and KBF-S ECO: 10–80 %KBF PRO: 10–98 %
- Models
- KBF and KBF PRO 130–1600; KBF-S ECO 240–1020

For materials and environmental testing: hot–cold cycles, rapid temperature changes (approx. 5 K/min) and ageing tests. The MKF and MKFT also control humidity. In the MK CO2 and MKF CO2 series, “CO2” stands for the natural refrigerant R-744.
- Temperature
- MK and MKF: from −40 to +180 °CMK CO2 and MKF CO2: from −48 to +180 °C (240 and 400: temporarily down to −50 °C)MKT and MKFT: from −70 to +180 °C
- Humidity
- MKF, MKF CO2, MKFT 240 and 720: 10–98 %MKFT 115: 10–95 %
- Models
- MK 56–1020; MKF 56–1020; MKT and MKFT 115–720; MK CO2 and MKF CO2 240–1020

For safe testing of lithium-ion battery cells, modules and packs. The chamber is equipped with a safety package matched to the EUCAR hazard level.
- Temperature
- packages A and P: from −70 to +120 °Cpackages P+, G and S: from −70 to +110 °C
- Base units
- MK, MKF, MKT and MKFT chambers, as well as KB and KT incubators
- Packages
- A (EUCAR 0–2), P (0–4), P+ (0–5), G (0–5), S (0–6)

Climate rooms for stability testing according to ICH Q1A and for storing large sample batches. Three standard sizes, and up to 60 m³ in the modular version.
- Temperature
- +5 to +50 °C, optionally from −20 °C
- Humidity
- 20–90 %
- Room volume
- WIC 1: 12.5 m³; WIC 2: 18.5 m³; WIC 3: 24.5 m³
Ultra-low temperature storage

For long-term storage of samples, vaccines and biological material. They cool with natural refrigerants, and vacuum insulation reduces energy consumption.
- Temperature
- from −90 to −40 °C
- Models
- UF V 350, UF V 500, UF V 700
Not sure what to choose? Describe your study and we will advise you.
Service, calibration and qualification
We are an authorised BINDER service centre. We look after equipment both under warranty and after the warranty has expired, and after measurements and qualifications we provide a certificate or documentation.
Warranty and post-warranty service
We repair and maintain BINDER equipment as the manufacturer's authorised service centre.
Calibration and adjustment
We calibrate and adjust all BINDER equipment. We confirm the result with a certificate.
DIN 12880 mapping
Temperature and humidity distribution at 1, 9 or 27 points, using instruments calibrated by the Central Office of Measures (GUM). We also measure light distribution.
IQ/OQ qualification
Installation and operational qualification with validation documentation.
Performance test
We check how long the unit takes to reach the set parameters.
Monitoring systems
For BINDER chambers with APT-COM™, and independent systems for other equipment and rooms.

Custom solutions
When a standard model is not enough, we adapt BINDER equipment to the standards and requirements of the specific study.
- Simulation of UVA or UVB radiation or the full sunlight spectrum (SUNLIGHT) in MK, MKT, MKF and MKFT chambers
- LED lighting in chambers and incubators
- Custom-designed condensation plates
UVB: 280–315 nm, UVA: 315–400 nm, visible light: 400–780 nm.
Catalogues to download
Current BINDER catalogues in PDF, no registration required. You will find data sheets for 122 models on the catalogues page.
PL, in PolishCO2 incubators CB-S, CB and CBF
PL, in PolishCooled incubators KT, KB ECO, KB and KB PRO
PL, in PolishStability test chambers KBF-S ECO, KBF and KBF PRO
PL, in PolishVacuum drying ovens VD and VDL
EN, in EnglishDrying ovens and heating chambers ED, ED-S, FD, FD-S, FED, FP and M
EN, in EnglishICH light modules for photostability testing
About us
We distribute laboratory equipment throughout Poland, with our sales office and service centre in Warsaw. We provide a full range of services: from selecting and purchasing equipment, through service, to calibration and validation. More about the company
BINDER is founded
A family-owned company from Tuttlingen, Germany.
SIMA becomes the authorised representative in Poland
Since that year we have been selling BINDER equipment and providing its warranty and post-warranty service.
Full range with service and validation
BINDER equipment from −90 to +300 °C, plus calibration with certificate, mapping according to DIN 12880 and IQ/OQ qualification.
BINDER specialises in environmental simulation chambers for scientific and industrial laboratories. It designs and manufactures its equipment in Germany.
Contact
Sales office and service
SIMA
ul. Pokrzywnicka 3a
04-320 Warszawa
- Opening hours
- 24h/7
Write to us
Choose a topic and describe what you need. We will reply by email or phone.
The data controller is „SIMA” s.c. P. Sikora, M. Gniadzik, ul. Pokrzywnicka 3a, 04-320 Warszawa. We will use the data from the form to reply to your message. More in our privacy policy.