Opens in a new tab

Authorised BINDER sales and service representative in Poland since 1997

BINDER stability test chambers

BINDER climate chambers for stability testing maintain constant temperature and humidity during long-term continuous operation, uniformly throughout the interior. They are used for testing pharmaceuticals according to ICH Q1A and Q1B and for shelf-life testing of cosmetics, food and materials, while large batches of samples will fit in a walk-in chamber. We will help you choose a model and, after purchase, take care of service, calibration, temperature and humidity distribution measurements according to DIN 12880 and IQ/OQ qualification.

Operating temperature range−20 to +100 °C

Applications

  • Drug stability studies according to ICH Q1A(R2): long-term, accelerated and stress testing
  • Photostability testing according to ICH Q1B
  • Shelf-life testing of cosmetics and food
  • Material testing and THB 85/85 testing (KBF PRO)
  • Accelerated ageing of medical device packaging (ASTM F1980)
  • Storage of large sample batches under constant climatic conditions
BINDER KBF 720 climate chamber

01 / 0316 models

KBF · KBF PRO · KBF-S ECO

Climate chambers for stability testing

For drug stability studies according to ICH Q1A: long-term, accelerated and stress studies, as well as for shelf-life testing of cosmetics and food. The chambers maintain the set temperature and humidity uniformly throughout the interior, even when fully loaded. There are three series to choose from, with volumes from 127 to 1.610 l.

  • APT.line™ preheating chamber: uniform climate even when fully loaded
  • Steam humidification and capacitive humidity sensor (KBF and KBF PRO)
  • Independent class 3.3 temperature safety device (DIN 12880) with alarm (KBF and KBF PRO)
  • Data logger with readout via USB, Ethernet interface; optional APT-COM™ GLP Edition (GLP, FDA 21 CFR Part 11)
  • Cooling with R-600a (KBF) or R-290 (KBF PRO) refrigerant; KBF-S ECO cools with a Peltier module, without refrigerant
  • Humidification water: demineralised, from a fixed water supply or from a canister (KBF-S ECO: canister only)
Temperature
KBF: 0 to +70 °CKBF PRO: −20 to +100 °CKBF-S ECO: 0 to +70 °C (max. 24–⁠28 °C below ambient temperature)
Humidity
KBF and KBF-S ECO: 10–⁠80 %KBF PRO: 10–⁠98 %
Humidity control in the temperature range
KBF: +10 to +70 °CKBF PRO: +10 to +90 °CKBF-S ECO: +5 to +70 °C
Constancy over time (25 °C and 60 % RH, 40 °C and 75 % RH)
temperature: ±0.1 Khumidity: KBF ±1.5 % RH, KBF PRO ±1 % RH, KBF-S ECO ±0.3–⁠0.4 % RH
Models
KBF and KBF PRO: 130, 260, 470, 720, 1060, 1600KBF-S ECO: 240, 400, 720, 1020

KBF Chambers with a wide temperature and humidity range

From 0 to +70 °C and from 10 to 80 % RH: for long-term, accelerated and stress testing according to ICH. KBF 130 units can be stacked; larger models stand on castors with brakes.

KBF models – technical data
ModelCapacityTemperatureHumidityEnergy consumption(25 °C, 60 % RH)External dimensions(W × H × D, mm)Data sheetEnquiry
KBF 130127 lfrom 0 to +70 °C10–⁠80 %215 Wh/h900 × 1005 × 710PDF, 0.7 MBEnquire
KBF 260262 lfrom 0 to +70 °C10–⁠80 %215 Wh/h930 × 1396 × 900PDF, 0.8 MBEnquire
KBF 470472 lfrom 0 to +70 °C10–⁠80 %265 Wh/h930 × 1951 × 900PDF, 0.7 MBEnquire
KBF 720727 lfrom 0 to +70 °C10–⁠80 %360 Wh/h1285 × 1951 × 900PDF, 0.7 MBEnquire
KBF 10601070 lfrom 0 to +70 °C10–⁠80 %365 Wh/h1285 × 1951 × 1175PDF, 0.8 MBEnquire
KBF 16001610 lfrom 0 to +70 °C10–⁠80 %395 Wh/h1795 × 1951 × 1175PDF, 0.8 MBEnquire

KBF PRO Chambers with an extended temperature and humidity range

From −20 to +100 °C and from 10 to 98 % RH, so also for material testing and THB testing at +85 °C and 85 % RH.

KBF PRO models – technical data
ModelCapacityTemperatureHumidityEnergy consumption(25 °C, 60 % RH)External dimensions(W × H × D, mm)Data sheetEnquiry
KBF PRO 130127 lfrom −20 to +100 °C10–⁠98 %235 Wh/h900 × 1005 × 710PDF, 0.7 MBEnquire
KBF PRO 260262 lfrom −20 to +100 °C10–⁠98 %235 Wh/h930 × 1396 × 900PDF, 0.8 MBEnquire
KBF PRO 470472 lfrom −20 to +100 °C10–⁠98 %245 Wh/h930 × 1951 × 900PDF, 0.7 MBEnquire
KBF PRO 720727 lfrom −20 to +100 °C10–⁠98 %390 Wh/h1285 × 1951 × 900PDF, 0.8 MBEnquire
KBF PRO 10601070 lfrom −20 to +100 °C10–⁠98 %400 Wh/h1285 × 1951 × 1175PDF, 0.8 MBEnquire
KBF PRO 16001610 lfrom −20 to +100 °C10–⁠98 %490 Wh/h1795 × 1951 × 1175PDF, 0.8 MBEnquire

KBF-S ECO Chambers with thermoelectric cooling (Peltier module)

It cools with a Peltier module, without refrigerant, and consumes 55–⁠90 Wh/h at 25 °C and 60 % RH. It cools down to 24–⁠28 °C below ambient temperature and draws humidification water from a canister.

KBF-S ECO models – technical data
ModelCapacityTemperatureHumidityEnergy consumption(25 °C, 60 % RH)External dimensions(W × H × D, mm)Data sheetEnquiry
KBF-S ECO 240247 lfrom 0 to +70 °C (max. 28 °C below ambient)10–⁠80 %55 Wh/h932 × 1461 × 796PDF, 0.6 MBEnquire
KBF-S ECO 400400 lfrom 0 to +70 °C (max. 26 °C below ambient)10–⁠80 %60 Wh/h925 × 1946 × 796PDF, 0.5 MBEnquire
KBF-S ECO 720700 l0 to +70 °C (max. 24 °C below ambient)10–⁠80 %90 Wh/h1254 × 1925 × 885PDF, 0.7 MBEnquire
KBF-S ECO 10201020 l0 to +70 °C (max. 24 °C below ambient)10–⁠80 %90 Wh/h1254 × 1925 × 1146PDF, 0.7 MBEnquire

External dimensions as specified by BINDER: housing without accessories or connections.

See also: Plant growth chambers: KBF and KBF PRO with LED module for plant illumination

BINDER KBF PRO 720 climate chamber with ICH light module; the module's control unit on the left side of the housing

02 / 03

KBF · KBF PRO · KB PRO with ICH module

Photostability test chambers

The ICH light module turns a KBF or KBF PRO chamber (sizes 260, 470 and 720) into a photostability test chamber according to ICH Q1B (option 2), and for tests without humidity control it also fits the KB PRO cooled incubator. Samples are exposed in sequence to visible light from LEDs and to UVA radiation from fluorescent tubes. A complete ICH test can be carried out in two days.

  • Separate VIS and UVA cassettes; after exposure to one source, the samples are moved under the other
  • LQC version: VIS and UVA sensors monitor the dose and switch off the light source once it has been reached
  • Light intensity limited to avoid thermal effects during the test
  • Lighting controlled by a time programme from the chamber controller
  • The module can be retrofitted later, on site; it fits current-generation chambers (E7)
  • Optional APT-COM™ GLP Edition: parameter recording compliant with GLP and FDA 21 CFR Part 11
Compliance
ICH Q1B, option 2
Light sources
VIS: LEDs, spectrum close to D65UVA: fluorescent tubes
Doses required by ICH Q1B
visible light: at least 1.2 million lx·hUVA (320–⁠400 nm): at least 200 Wh/m²
Modules
ICH 260/470 and ICH 720with dose control: ICH-LQC 260/470 and ICH-LQC 720
Chamber with ICH module: climate range with lighting switched on
Base unitLight moduleTemperatureHumidity
KBF 260, KBF 470ICH 260/470 or ICH-LQC 260/470from +20 to +50 °C20–⁠50 %
KBF 720ICH 720 or ICH-LQC 720from +20 to +50 °C20–⁠50 %
KBF PRO 260, KBF PRO 470ICH 260/470 or ICH-LQC 260/470from +10 to +50 °C10–⁠80 %
KBF PRO 720ICH 720 or ICH-LQC 720from +10 to +50 °C10–⁠80 %
KB PRO 260, KB PRO 470 (cooled incubator)ICH 260/470 or ICH-LQC 260/470from +5 to +60 °Cnot controlled
KB PRO 720 (cooled incubator)ICH 720 or ICH-LQC 720from +5 to +60 °Cnot controlled
BINDER WIC 2 walk-in chamber

03 / 033 models

WIC 1 · WIC 2 · WIC 3

Walk-in chambers

Chambers you can walk into, for long-term and accelerated stability studies according to ICH Q1A(R2) and for storing large batches of samples. Three standard sizes with volumes of approx. 12.5 m³, 18.5 m³ and 24.5 m³, and up to 60 m³ in the modular version, with dimensions, doors and windows adapted to the room.

  • Stainless steel interior and floor, floor load capacity 50.000 N/m²
  • Walls made of panels with 100 mm PU foam (U = 0.21 W/m²K)
  • LED lighting with motion sensor
  • Air-conditioning unit at the rear of the chamber (optionally at the front), with service access from outside
  • Refrigerant with a GWP of 547
  • Additional equipment: stainless steel shelving, ramp, 30 and 50 mm access ports, PVC strip curtain, APT-COM™-compatible monitoring system
Temperature
+5 to +50 °C, optionally from −20 °C
Humidity
20–⁠90 %
Capacity
WIC 1: 12.5 m³, WIC 2: 18.5 m³, WIC 3: 24.5 m³modular version: up to 60 m³
Uniformity and constancy
temperature: ±1.5 K spatially, ±0.5 K over timehumidity: ±2.5 % RH over time
Power supply
230 V, 50 Hz, 1 phase; power 2.7 kW

WIC Walk-in chambers in standard sizes

Externally, each is 2.6 m wide and 2.47 m high, with a length of 2.5, 3.6 or 4.7 m. The interior is 2.27 m high.

WIC models – technical data
ModelCapacityTemperatureHumidityExternal dimensions(W × H × D, mm)Data sheetEnquiry
WIC 112.530 lfrom +5 to +50 °C20–⁠90 %2600 × 2470 × 2500PDF, 1.3 MBEnquire
WIC 218.523 lfrom +5 to +50 °C20–⁠90 %2600 × 2470 × 3600PDF, 1.9 MBEnquire
WIC 324.516 lfrom +5 to +50 °C20–⁠90 %2600 × 2470 × 4700PDF, 1.7 MBEnquire

External dimensions as specified by BINDER: housing without accessories or connections.

Service, calibration and qualification

We are an authorised BINDER service provider. We look after equipment both under warranty and after the warranty has expired, calibrate it, measure temperature distribution according to DIN 12880 and carry out IQ/OQ qualification.

Contact

Sales office and service

SIMA
ul. Pokrzywnicka 3a
04-320 Warszawa

Show on map

Opening hours
24h/7

Write to us

Choose a topic and describe what you need. We will reply by email or phone.

What is your message about?

The data controller is „SIMA” s.c. P. Sikora, M. Gniadzik, ul. Pokrzywnicka 3a, 04-320 Warszawa. We will use the data from the form to reply to your message. More in our privacy policy.