BINDER battery test chambers
BINDER battery test chambers are used for ageing, performance and abuse testing of lithium-ion cells, modules and complete systems. The safety packages are matched to the EUCAR hazard levels, a scale from 0 (no effect) to 7 (explosion), and cover levels 0 to 6. The chambers are used in research and development, quality control and production, also together with cyclers and chillers from other manufacturers.
Operating temperature range−70 to +120 °C

Applications
- Ageing tests: cyclic and calendar
- Performance tests at different temperatures: capacity, internal resistance, self-discharge
- Abuse tests up to EUCAR hazard level 6
- Charging and discharging of coin, prismatic and pouch cells as well as modules
- Battery research and development, quality control and production
A · P · P+ · G · S
Chambers with safety packages A, P, P+, G and S
Each chamber is configured individually: a proven series-production unit, e.g. a dynamic climate chamber or a cooled incubator, is combined with one of five safety packages. Configuration starts with a feasibility analysis, after which BINDER recommends the base unit. We will select the safety package to suit your tests.
- Packages for EUCAR hazard levels 0 to 6
- Every package includes an independent, intrinsically safe class 2 temperature limiter, factory-set to 120 °C
- From package P upwards: door lock with two reinforced clamps, 150 mm pressure relief flap and inert gas connection
- From package P+ upwards: connection for an independent CO2 cooling and flushing system that reduces the risk of fire
- Gas detection: CO in package G; H2, CO and O2 in package S
- On request: additional access ports, a reinforced inner chamber or shelves
- EUCAR hazard levels
- A: 0–2P: 0–4P+ and G: 0–5S: 0–6
- Temperature
- packages A and P: −70 to +120 °Cpackages P+, G and S: −70 to +110 °Cthe range also depends on the base unit (e.g. cooled incubators: −20 to +100 °C)
- Base units
- e.g. BINDER dynamic climate chambers or cooled incubators
- Integration
- cyclers and chillers from other manufacturersEthernet (Modbus TCP), optional RS485 (Modbus RTU)remote monitoring via APT-COM™ 4
- Options
- emergency stop buttonelectromechanical door locking (A, P, P+)200 mm overpressure flap (P, P+, G, S)flexible temperature sensor (P+, G, S)
| Package | EUCAR levels | Temperature range | Purpose and standard equipment |
|---|---|---|---|
| Package A | 0–2 | from −70 to +120 °C | Ageing tests on non-powered energy storage devices. Independent, intrinsically safe class 2 temperature limiter, factory-set to 120 °C. |
| Package P | 0–4 | from −70 to +120 °C | Ageing and performance tests. As A, plus a mechanical door lock with two reinforced latches, a 150 mm reversible pressure relief flap and an inert gas connection for continuous inerting (without control). |
| Package P+ | 0–5 | from −70 to +110 °C | Extended performance tests. As P, plus a connection for a CO2 cooling and purging system, triggered by an additional independent temperature sensor at 120 °C or manually, and an audible and visual alarm. |
| Package G | 0–5 | from −70 to +110 °C | Extended performance tests with advanced detection. As P+, plus a CO sensor that triggers CO2 cooling and purging, a three-colour signal light with audible alarm and electromechanical door locking. |
| Package S | 0–6 | from −70 to +110 °C | Stress tests. As G, but with H2, CO and O2 detection (triggers cooling and purging) and a controlled inerting system. |
Service, calibration and qualification
We are an authorised BINDER service centre: we look after units both under warranty and after it has expired. Ask about calibration and IQ/OQ qualification of a chamber with a safety package when requesting a quote.
Contact
Sales office and service
SIMA
ul. Pokrzywnicka 3a
04-320 Warszawa
- Opening hours
- 24h/7
Write to us
Choose a topic and describe what you need. We will reply by email or phone.
The data controller is „SIMA” s.c. P. Sikora, M. Gniadzik, ul. Pokrzywnicka 3a, 04-320 Warszawa. We will use the data from the form to reply to your message. More in our privacy policy.