BINDER laboratory incubators
BINDER incubators provide constant conditions for culturing microorganisms, cells and tissues. Standard incubators (heating incubators) operate above ambient temperature, cooled models below it as well, and CO2 incubators also maintain the CO2 concentration and high humidity. We will help you choose a model and, after purchase, take care of service, calibration, mapping according to DIN 12880 and IQ/OQ qualification.
Operating temperature range−20 to +100 °C

Applications
- Cultivation of microbiological cultures
- Hygiene control and food testing
- Water analysis and environmental monitoring
- Cell and tissue cultures
- In vitro fertilisation and diagnostics
- Sample cooling and storage

B · BD · BD-S · BF
Standard incubators (heating incubators)
Heating incubators maintain a temperature above ambient. They are used for culturing and incubating microbiological cultures and for routine laboratory tests, from hygiene control to microbiology. The BD series with natural convection is suitable for gentle incubation, while the BF with forced air circulation restores the temperature faster after the door is opened and performs well at full load.
- APT.line™ preheating chamber (BD, BD-S, BF) – high temperature accuracy
- Inner safety glass door on all models
- Disinfection at 100 °C (BD and BF)
- Independent class 3.1 temperature safety device according to DIN 12880 (BD, BD-S, BF)
- USB port for data logging (BD and BF 56, 115, 260, 720)
- Temperature
- BD: from ambient +5 °C to +100 °CBF: from ambient +5–10 °C (depending on model) to +100 °CBD-S: from ambient +5 °C to +70 °CB 28: from +30 to +70 °C
- Spatial variation at 37 °C
- BF: ±0.2–0.4 KBD: ±0.3–0.7 KBD-S: ±0.5 KB 28: ±1.5 K
- Capacity
- 20–737 l
- Models
- B 28; BD 23–720; BD-S 56 and 115; BF 56–720

B Incubator with analogue control
A 28 l incubator with a hydraulic-mechanical thermostat, operating in the range from +30 to +70 °C. It has an inner safety glass door.
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Heat-up to 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| B 28 | 28 l | from +30 to +70 °C | ±1.5 K | 95 min | 580 × 405 × 425 | PDF, 0.5 MB | Enquire |

BD Incubators with natural convection
Natural air circulation for gentle incubation of organisms and conditioning of heat-sensitive media. Six sizes: from 20 to 737 l.
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Heat-up to 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| BD 23 | 20 l | from ambient +5 to +100 °C | ±0.5 K | 59 min | 435 × 495 × 520 | PDF, 0.3 MB | Enquire |
| BD 56 | 57 l | from ambient +5 to +100 °C | ±0.3 K | 52 min | 560 × 625 × 565 | PDF, 0.7 MB | Enquire |
| BD 115 | 112 l | from ambient +5 to +100 °C | ±0.3 K | 55 min | 710 × 705 × 605 | PDF, 0.7 MB | Enquire |
| BD 260 | 253 l | from ambient +5 to +100 °C | ±0.3 K | 60 min | 810 × 940 × 760 | PDF, 0.7 MB | Enquire |
| BD 400 | 400 l | from ambient +5 to +100 °C | ±0.5 K | 120 min | 1235 × 1025 × 765 | PDF, 1.1 MB | Enquire |
| BD 720 | 737 l | from ambient +5 to +100 °C | ±0.7 K | 70 min | 1165 × 1590 × 870 | PDF, 0.4 MB | Enquire |

BD-S Solid.Line incubators with natural convection
Natural convection, a range up to +70 °C and a controller with timer; for incubation in research and quality control. Two sizes: 62 and 118 l.
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Heat-up to 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| BD-S 56 | 62 l | from ambient +5 to +70 °C | ±0.5 K | 230 min | 614 × 625 × 577 | PDF, 0.4 MB | Enquire |
| BD-S 115 | 118 l | from ambient +5 to +70 °C | ±0.5 K | 250 min | 765 × 735 × 616 | PDF, 0.4 MB | Enquire |

BF Incubators with forced convection
Forced air circulation keeps conditions uniform even when fully loaded, and after the door has been open for 30 s the temperature returns to 37 °C within 3–5 min.
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Heat-up to 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| BF 56 | 59 l | from ambient +7 to +100 °C | ±0.2 K | 6 min | 560 × 625 × 565 | PDF, 0.7 MB | Enquire |
| BF 115 | 114 l | from ambient +8 to +100 °C | ±0.3 K | 8 min | 710 × 725 × 605 | PDF, 0.7 MB | Enquire |
| BF 260 | 257 l | from ambient +7 to +100 °C | ±0.2 K | 7 min | 810 × 845 × 760 | PDF, 0.7 MB | Enquire |
| BF 400 | 400 l | from ambient +5 to +100 °C | ±0.4 K | 12 min | 1235 × 1025 × 765 | PDF, 1.1 MB | Enquire |
| BF 720 | 734 l | from ambient +10 to +100 °C | ±0.3 K | 15 min | 1165 × 1590 × 870 | PDF, 0.4 MB | Enquire |
External dimensions as specified by BINDER: housing without accessories or connections.
BINDER materials to download

KB · KB PRO · KB ECO · KT
Cooled incubators
Cooled incubators both heat and cool, so they can incubate and store samples even below ambient temperature – in microbiology, pharmaceutical research, the food industry and environmental monitoring. KB and KB PRO are cooled by a compressor, while KB ECO and KT use a Peltier module – they consume less energy and need no refrigerant. If you need a temperature well below ambient, or a heat-emitting device operates inside the chamber, choose compressor cooling.
- APT.line™ preheating chamber: uniform temperature even when fully loaded
- Temperature programming, e.g. cooling samples to +4 °C over the weekend
- Internal data logger with USB readout, Ethernet interface
- Hot-air disinfection at 100 °C (KB, KT)
- KB PRO: optional CO2 gassing, LED modules for plant cultivation (260–1600) and ICH light modules (260–720)
- Temperature
- KB: from 0 to +70 °CKB PRO: from −20 to +100 °CKB ECO: from 0 to +70 °C (max. 26–28 °C below ambient)KT: from +4 to +100 °C
- Cooling
- KB: compressor, refrigerant R-600aKB PRO: compressor, refrigerant R-290KB ECO and KT: Peltier module, no refrigerant
- Capacity
- 53–1610 l
- Models
- KB 65–1060; KB PRO 130–1600; KB ECO 240–1020; KT 53–170

KB Incubators with compressor cooling
For incubating microorganisms from 0 to +70 °C, with precision even when fully loaded. Thanks to inverter cooling, they use up to 40 % less energy than the previous KB model.
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Energy consumption at 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| KB 65 | 63 l | from 0 to +70 °C | ±0.2 K | 90 Wh/h | 650 × 905 × 710 | PDF, 0.4 MB | Enquire |
| KB 130 | 127 l | from 0 to +70 °C | ±0.2 K | 125 Wh/h | 900 × 1005 × 710 | PDF, 0.5 MB | Enquire |
| KB 260 | 262 l | from 0 to +70 °C | ±0.2 K | 140 Wh/h | 930 × 1396 × 900 | PDF, 0.6 MB | Enquire |
| KB 470 | 472 l | from 0 to +70 °C | ±0.2 K | 140 Wh/h | 930 × 1951 × 900 | PDF, 0.5 MB | Enquire |
| KB 720 | 727 l | from 0 to +70 °C | ±0.2 K | 255 Wh/h | 1285 × 1951 × 900 | PDF, 0.6 MB | Enquire |
| KB 1060 | 1070 l | from 0 to +70 °C | ±0.2 K | 260 Wh/h | 1285 × 1951 × 1175 | PDF, 0.7 MB | Enquire |

KB PRO Incubators with extended temperature range
They operate from −20 to +100 °C and have a touchscreen controller with time programmes. With optional light modules, they serve as ICH photostability test chambers (260–720) or for plant cultivation (260–1600).
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Energy consumption at 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| KB PRO 130 | 127 l | from −20 to +100 °C | ±0.2 K | 160 Wh/h | 900 × 1005 × 710 | PDF, 0.5 MB | Enquire |
| KB PRO 260 | 262 l | from −20 to +100 °C | ±0.2 K | 185 Wh/h | 930 × 1396 × 900 | PDF, 0.6 MB | Enquire |
| KB PRO 470 | 472 l | from −20 to +100 °C | ±0.2 K | 205 Wh/h | 930 × 1951 × 900 | PDF, 0.5 MB | Enquire |
| KB PRO 720 | 727 l | from −20 to +100 °C | ±0.2 K | 330 Wh/h | 1285 × 1951 × 900 | PDF, 0.6 MB | Enquire |
| KB PRO 1060 | 1070 l | from −20 to +100 °C | ±0.2 K | 340 Wh/h | 1285 × 1951 × 1175 | PDF, 0.7 MB | Enquire |
| KB PRO 1600 | 1610 l | from −20 to +100 °C | ±0.2 K | 370 Wh/h | 1795 × 1951 × 1175 | PDF, 0.7 MB | Enquire |

KB ECO Free-standing incubators with Peltier module
They operate from 0 to +70 °C, but cool the chamber to no more than 26–28 °C below ambient temperature. They are quiet, economical and need no refrigerant.
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Energy consumption at 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| KB ECO 240 | 247 l | from 0 to +70 °C (max. 28 °C below ambient) | ±0.1 K | 65 Wh/h | 925 × 1461 × 796 | PDF, 0.6 MB | Enquire |
| KB ECO 400 | 400 l | from 0 to +70 °C (max. 28 °C below ambient) | ±0.1 K | 70 Wh/h | 925 × 1946 × 796 | PDF, 0.5 MB | Enquire |
| KB ECO 720 | 700 l | from 0 to +70 °C (max. 26 °C below ambient) | ±0.1 K | 105 Wh/h | 1250 × 1925 × 885 | PDF, 0.7 MB | Enquire |
| KB ECO 1020 | 1020 l | from 0 to +70 °C (max. 26 °C below ambient) | ±0.1 K | 105 Wh/h | 1250 × 1925 × 1149 | PDF, 0.6 MB | Enquire |

KT Benchtop incubators with Peltier module
They operate from +4 to +100 °C and offer time-segment programming and hot-air disinfection at 100 °C. They ensure reproducible incubation even at high ambient temperatures.
| Model | Capacity | Temperature range | Variation at 37 °C(spatial) | Energy consumption at 37 °C | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| KT 53 | 53 l | from +4 to +100 °C | ±0.3 K | 75 Wh/h | 660 × 635 × 630 | PDF, 0.4 MB | Enquire |
| KT 115 | 102 l | from +4 to +100 °C | ±0.3 K | 75 Wh/h | 860 × 715 × 655 | PDF, 0.4 MB | Enquire |
| KT 170 | 163 l | from +4 to +100 °C | ±0.4 K | 80 Wh/h | 860 × 1025 × 655 | PDF, 0.5 MB | Enquire |
External dimensions as specified by BINDER: housing without accessories or connections.
BINDER materials to download
See also: Plant growth chambers: KB PRO, KBF and KBF PRO with LED module Battery test chambers with safety packages

CB · CB-S · CBF
CO2 incubators
CO2 incubators maintain the temperature, CO2 concentration and high humidity needed for cell and tissue culture – in medical research, pharmaceuticals, diagnostics and in vitro fertilisation. All models are hot-air sterilised at 180 °C, and the CO2 concentration is measured by an infrared sensor.
- Hot-air sterilisation at 180 °C in all series
- Infrared CO2 sensor; in CB and CBF also sterilised with hot air
- Seamless stainless steel chamber, fan-free, easy to clean
- Humidification: water pan (CB-S), PERMADRY system (CB), active humidification with sterile steam (CBF)
- CB and CBF: touchscreen controller and CO2 Fail Safe system
- Data logger with USB readout; Ethernet and USB interfaces and a potential-free alarm contact
- Temperature
- CB: from ambient +4–5 °C (depending on model) to +50 °CCB-S and CBF: from ambient +6 °C to +50 °CCB 170 and CB 260 with O2 control: from ambient +6 °C to +50 °C
- CO2
- 0–20 %, infrared (IR) sensor
- Humidity
- CB and CB-S: 90–95 %CBF: 50–95 %, active steam humidification
- O2 (optional)
- CB 170, CB 260, CBF 170 and CBF 260: 0.2–20 %, optionally 10–90 %
- Models
- CB 56, 170, 260; CB-S 170, 260; CBF 170, 260

CB CO2 incubators with sterilisable CO2 sensor
For cell-based testing, active substance research and medical research. PERMADRY humidification and a CO2 sensor sterilised with hot air; CB 170 and CB 260 also with O2 control.
| Model | Capacity | Temperature range | Humidity | CO2 | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| CB 56 | 53 l | from ambient +4 to +50 °C | 90–95 % | 0–20 % vol. | 528 × 674 × 545 | PDF, 0.5 MB | Enquire |
| CB 170 | 170 l | from ambient +4 to +50 °C | 90–95 % | 0–20 % vol. | 680 × 870 × 715 | PDF, 0.5 MB | Enquire |
| CB 260 | 267 l | from ambient +5 to +50 °C | 90–95 % | 0–20 % vol. | 740 × 1020 × 785 | PDF, 0.5 MB | Enquire |
Data for the standard version. Versions with O2 control (CB 170 and CB 260): from ambient +6 to +50 °C, O2 0.2–20 % (optionally 10–90 %).

CB-S CO2 incubators for routine cell culture
For standard cell culture, cell production and academic applications. Sterilisation at 180 °C, infrared CO2 sensor and humidification from a water pan.
| Model | Capacity | Temperature range | Humidity | CO2 | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| CB-S 170 | 170 l | from ambient +6 to +50 °C | 90–95 % | 0–20 % vol. | 680 × 870 × 715 | PDF, 0.4 MB | Enquire |
| CB-S 260 | 267 l | from ambient +6 to +50 °C | 90–95 % | 0–20 % vol. | 740 × 1020 × 785 | PDF, 0.5 MB | Enquire |

CBF CO2 incubators with humidity control
For GMP-compliant environments, stem cell research and cell and gene therapy. Active humidification with sterile steam in the range 50–95 %; both models also with O2 control.
| Model | Capacity | Temperature range | Humidity | CO2 | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| CBF 170 | 170 l | from ambient +6 to +50 °C | 50–95 % | 0–20 % vol. | 680 × 870 × 715 | PDF, 0.4 MB | Enquire |
| CBF 260 | 267 l | from ambient +6 to +50 °C | 50–95 % | 0–20 % vol. | 740 × 1020 × 785 | PDF, 0.5 MB | Enquire |
External dimensions as specified by BINDER: housing without accessories or connections.
BINDER materials to download
Service, calibration and qualification
We are an authorised BINDER service provider. We look after equipment both under warranty and after the warranty has expired, calibrate it, measure temperature distribution according to DIN 12880 and carry out IQ/OQ qualification.
Contact
Sales office and service
SIMA
ul. Pokrzywnicka 3a
04-320 Warszawa
- Opening hours
- 24h/7
Write to us
Choose a topic and describe what you need. We will reply by email or phone.
The data controller is „SIMA” s.c. P. Sikora, M. Gniadzik, ul. Pokrzywnicka 3a, 04-320 Warszawa. We will use the data from the form to reply to your message. More in our privacy policy.