BINDER climate and test chambers
BINDER dynamic climate chambers are used for temperature and climate testing of materials, components and assemblies: from −70 to +180 °C, and the MKF, MKF CO2 and MKFT series also control relative humidity in the range 10–98 %. The average rate of temperature change according to IEC 60068-3-5 is 4.0–6.2 K/min, which allows you to run cyclic hot–cold tests and reproducible, standard-compliant testing. We will help you select the series and chamber size, and after purchase we take care of service, calibration and IQ/OQ qualification.
Operating temperature range−70 to +180 °C

Applications
- Cyclic hot–cold tests
- Temperature and humidity tests according to DIN and IEC standards
- Testing of electronics and components, including those powered during the test
- Service life tests in the automotive, aviation and space industries
- Materials testing in electrical engineering and industry
- Battery testing (with safety package)
MK · MK CO2 · MKT · MKF · MKF CO2 · MKFT
Dynamic climate chambers
The six series differ in their lower temperature limit (from −40 to −70 °C), humidity control and refrigerant. The series with the suffix CO2 are the new generation, cooled with the natural refrigerant R-744, which cools the chamber down in a shorter time. We can also adapt MK, MKT, MKF and MKFT chambers to simulate UVA or UVB radiation or the full spectrum of sunlight.
- The APT.line™ preheating chamber ensures homogeneous conditions
- Segment programs, real-time programming and ramp function
- Data logger with USB readout and APT-COM™ Basic Edition software
- Programmable condensation protection for samples
- Viewing window with interior lighting and 50 or 80 mm access port (sizes 720 and 1020: two 80 mm ports)
- MKF, MKF CO2 and MKFT: steam humidification and capacitive humidity sensor
- Temperature
- MK and MKF: −40 to +180 °CMK CO2 and MKF CO2: −48 to +180 °C (sizes 240 and 400: temporarily down to −50 °C)MKT and MKFT: −70 to +180 °C
- Humidity
- MKF and MKF CO2: 10–98 %MKFT 240 and 720: 10–98 %MKFT 115: 10–95 %MK, MK CO2 and MKT: no humidity control
- Rate of temperature change
- heating: average 4.0–6.2 K/mincooling: average 4.0–5.7 K/minaccording to IEC 60068-3-5, in the range from −40 to +180 °C
- Capacity
- from 60 to 991 l (sizes 56–1020)
- Refrigerant
- MK and MKF: R-452AMKT and MKFT: R-452A and R-23, cascade coolingMK CO2 and MKF CO2: CO2 (R-744), GWP 1
- Power supply
- size 56: 230 Vother sizes: 400 V, three-phase

MK Temperature test chambers
For heat and cold tests and cyclic temperature tests from −40 to +180 °C, without humidity control. Cooling is provided by a compressor unit with R-452A refrigerant.
| Model | Capacity | Temperature range | Heating rate(average acc. to IEC 60068-3-5) | Cooling rate(average acc. to IEC 60068-3-5) | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| MK 56 | 60 l | from −40 to +180 °C | 5.0 K/min | 5.0 K/min | 720 × 1445 × 778 | PDF, 0.7 MB | Enquire |
| MK 115 | 115 l | from −40 to +180 °C | 5.3 K/min | 5.0 K/min | 980 × 1725 × 865 | PDF, 0.8 MB | Enquire |
| MK 240 | 228 l | from −40 to +180 °C | 5.0 K/min | 4.5 K/min | 1115 × 1710 × 925 | PDF, 1.0 MB | Enquire |
| MK 400 | 417 l | from −40 to +180 °C | 5.0 K/min | 5.0 K/min | 1115 × 1710 × 1400 | PDF, 0.9 MB | Enquire |
| MK 720 | 734 l | from −40 to +180 °C | 4.0 K/min | 4.5 K/min | 1580 × 2005 × 1140 | PDF, 0.9 MB | Enquire |
| MK 1020 | 991 l | from −40 to +180 °C | 5.5 K/min | 5.0 K/min | 1580 × 2005 × 1480 | PDF, 0.9 MB | Enquire |

MK CO2 Temperature test chambers with CO2 refrigerant
The new generation of MK chambers, cooled with the natural refrigerant CO2 (R-744), from −48 to +180 °C (sizes 240 and 400: temporarily down to −50 °C). It cools from +180 to −40 °C in 60–80 min (MK of the same size: 100–120 min), and its high cooling capacity makes it possible to compensate for the heat given off by the samples.
| Model | Capacity | Temperature range | Heating rate(average acc. to IEC 60068-3-5) | Cooling rate(average acc. to IEC 60068-3-5) | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| MK 240 CO2 | 228 l | from −50 to +180 °C | 5.5 K/min | 5.7 K/min | 1115 × 1710 × 925 | PDF, 0.7 MB | Enquire |
| MK 400 CO2 | 417 l | from −50 to +180 °C | 5.7 K/min | 5.0 K/min | 1115 × 1710 × 1400 | PDF, 0.7 MB | Enquire |
| MK 720 CO2 | 734 l | from −48 to +180 °C | 4.5 K/min | 5.7 K/min | 1580 × 2005 × 1140 | PDF, 0.8 MB | Enquire |
| MK 1020 CO2 | 991 l | from −48 to +180 °C | 6.2 K/min | 4.8 K/min | 1580 × 2005 × 1480 | PDF, 0.7 MB | Enquire |
The MK 240 CO2 and MK 400 CO2 reach −50 °C only temporarily: according to BINDER, the temperature can be lowered to −50 °C for a maximum of 8 hours. In continuous operation, the range starts at −48 °C.

MKT Temperature test chambers down to −70 °C
Extended low-temperature range, from −70 to +180 °C, for cyclic temperature tests. Cooling is provided by a cascade refrigeration unit with R-452A and R-23 refrigerants.
| Model | Capacity | Temperature range | Heating rate(average acc. to IEC 60068-3-5) | Cooling rate(average acc. to IEC 60068-3-5) | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| MKT 115 | 115 l | from −70 to +180 °C | 5.3 K/min | 4.2 K/min | 980 × 1725 × 865 | PDF, 0.8 MB | Enquire |
| MKT 240 | 228 l | from −70 to +180 °C | 5.0 K/min | 4.2 K/min | 1115 × 1935 × 925 | PDF, 0.7 MB | Enquire |
| MKT 720 | 734 l | from −70 to +180 °C | 4.5 K/min | 4.0 K/min | 1580 × 2005 × 1140 | PDF, 0.9 MB | Enquire |

MKF Chambers with humidity control
For heat, cold and humidity tests according to DIN and IEC standards: from −40 to +180 °C and 10–98 %. Steam humidification; sizes 240–1020 have a built-in 20 l water tank.
| Model | Capacity | Temperature range | Heating rate(average acc. to IEC 60068-3-5) | Cooling rate(average acc. to IEC 60068-3-5) | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| MKF 56 | 60 l | from −40 to +180 °C | 5.0 K/min | 5.0 K/min | 720 × 1445 × 780 | PDF, 0.8 MB | Enquire |
| MKF 240 | 228 l | from −40 to +180 °C | 5.0 K/min | 5.0 K/min | 1115 × 1715 × 925 | PDF, 1.2 MB | Enquire |
| MKF 400 | 417 l | from −40 to +180 °C | 5.0 K/min | 5.0 K/min | 1115 × 1710 × 1400 | PDF, 1.0 MB | Enquire |
| MKF 720 | 734 l | from −40 to +180 °C | 4.8 K/min | 4.8 K/min | 1580 × 2005 × 1140 | PDF, 1.1 MB | Enquire |
| MKF 1020 | 991 l | from −40 to +180 °C | 5.5 K/min | 5.0 K/min | 1580 × 2005 × 1480 | PDF, 1.0 MB | Enquire |

MKF CO2 Chambers with humidity control and CO2 refrigerant
Combined tests of temperature from −48 to +180 °C (sizes 240 and 400: temporarily down to −50 °C) and humidity at 10–98 %, with the natural refrigerant CO2 (R-744). It cools from +180 to −40 °C in 60–80 min (MKF of the same size: 115–120 min); 20 l water tank as standard.
| Model | Capacity | Temperature range | Heating rate(average acc. to IEC 60068-3-5) | Cooling rate(average acc. to IEC 60068-3-5) | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| MKF 240 CO2 | 228 l | from −50 to +180 °C | 5.5 K/min | 5.7 K/min | 1115 × 1713 × 925 | PDF, 0.9 MB | Enquire |
| MKF 400 CO2 | 417 l | from −50 to +180 °C | 5.7 K/min | 5.0 K/min | 1115 × 1727 × 1400 | PDF, 0.9 MB | Enquire |
| MKF 720 CO2 | 734 l | from −48 to +180 °C | 5.1 K/min | 5.7 K/min | 1580 × 2005 × 1140 | PDF, 0.9 MB | Enquire |
| MKF 1020 CO2 | 991 l | from −48 to +180 °C | 6.2 K/min | 4.8 K/min | 1580 × 2005 × 1480 | PDF, 0.9 MB | Enquire |
The MKF 240 CO2 and MKF 400 CO2 reach −50 °C only temporarily: according to BINDER, the temperature can be lowered to −50 °C for a maximum of 8 hours. In continuous operation, the range starts at −48 °C.

MKFT Chambers with humidity control, down to −70 °C
For complex climate tests from −70 to +180 °C with humidity control at 10–98 % (MKFT 115: 10–95 %). Cascade refrigeration unit (R-452A and R-23), steam humidification and 20 l water tank.
| Model | Capacity | Temperature range | Heating rate(average acc. to IEC 60068-3-5) | Cooling rate(average acc. to IEC 60068-3-5) | External dimensions(W × H × D, mm) | Data sheet | Enquiry |
|---|---|---|---|---|---|---|---|
| MKFT 115 | 115 l | from −70 to +180 °C | 5.5 K/min | 4.2 K/min | 980 × 1725 × 865 | PDF, 1.0 MB | Enquire |
| MKFT 240 | 228 l | from −70 to +180 °C | 5.0 K/min | 4.2 K/min | 1115 × 1940 × 925 | PDF, 0.9 MB | Enquire |
| MKFT 720 | 734 l | from −70 to +180 °C | 4.8 K/min | 4.0 K/min | 1580 × 2005 × 1140 | PDF, 1.1 MB | Enquire |
External dimensions as specified by BINDER: housing without accessories or connections.
BINDER materials to download
See also: Battery test chambers with safety packages Custom solutions: UVA, UVB and sunlight simulation
Service, calibration and qualification
We are an authorised BINDER service provider. We look after equipment both under warranty and after the warranty has expired, calibrate it, measure temperature distribution according to DIN 12880 and carry out IQ/OQ qualification.
Contact
Sales office and service
SIMA
ul. Pokrzywnicka 3a
04-320 Warszawa
- Opening hours
- 24h/7
Write to us
Choose a topic and describe what you need. We will reply by email or phone.
The data controller is „SIMA” s.c. P. Sikora, M. Gniadzik, ul. Pokrzywnicka 3a, 04-320 Warszawa. We will use the data from the form to reply to your message. More in our privacy policy.