BINDER climate and test chambers

BINDER dynamic climate chambers are used for temperature and climate testing of materials, components and assemblies: from −70 to +180 °C, and the MKF, MKF CO2 and MKFT series also control relative humidity in the range 10–⁠98 %. The average rate of temperature change according to IEC 60068-3-5 is 4.0–⁠6.2 K/min, which allows you to run cyclic hot–cold tests and reproducible, standard-compliant testing. We will help you select the series and chamber size, and after purchase we take care of service, calibration and IQ/OQ qualification.

Operating temperature range−70 to +180 °C

Applications

  • Cyclic hot–cold tests
  • Temperature and humidity tests according to DIN and IEC standards
  • Testing of electronics and components, including those powered during the test
  • Service life tests in the automotive, aviation and space industries
  • Materials testing in electrical engineering and industry
  • Battery testing (with safety package)

25 models

MK · MK CO2 · MKT · MKF · MKF CO2 · MKFT

Dynamic climate chambers

The six series differ in their lower temperature limit (from −40 to −70 °C), humidity control and refrigerant. The series with the suffix CO2 are the new generation, cooled with the natural refrigerant R-744, which cools the chamber down in a shorter time. We can also adapt MK, MKT, MKF and MKFT chambers to simulate UVA or UVB radiation or the full spectrum of sunlight.

  • The APT.line™ preheating chamber ensures homogeneous conditions
  • Segment programs, real-time programming and ramp function
  • Data logger with USB readout and APT-COM™ Basic Edition software
  • Programmable condensation protection for samples
  • Viewing window with interior lighting and 50 or 80 mm access port (sizes 720 and 1020: two 80 mm ports)
  • MKF, MKF CO2 and MKFT: steam humidification and capacitive humidity sensor
Temperature
MK and MKF: −40 to +180 °CMK CO2 and MKF CO2: −48 to +180 °C (sizes 240 and 400: temporarily down to −50 °C)MKT and MKFT: −70 to +180 °C
Humidity
MKF and MKF CO2: 10–⁠98 %MKFT 240 and 720: 10–⁠98 %MKFT 115: 10–⁠95 %MK, MK CO2 and MKT: no humidity control
Rate of temperature change
heating: average 4.0–⁠6.2 K/mincooling: average 4.0–⁠5.7 K/minaccording to IEC 60068-3-5, in the range from −40 to +180 °C
Capacity
from 60 to 991 l (sizes 56–⁠1020)
Refrigerant
MK and MKF: R-452AMKT and MKFT: R-452A and R-23, cascade coolingMK CO2 and MKF CO2: CO2 (R-744), GWP 1
Power supply
size 56: 230 Vother sizes: 400 V, three-phase

MK Temperature test chambers

For heat and cold tests and cyclic temperature tests from −40 to +180 °C, without humidity control. Cooling is provided by a compressor unit with R-452A refrigerant.

MK models – technical data
ModelCapacityTemperature rangeHeating rate(average acc. to IEC 60068-3-5)Cooling rate(average acc. to IEC 60068-3-5)External dimensions(W × H × D, mm)Data sheetEnquiry
MK 5660 lfrom −40 to +180 °C5.0 K/min5.0 K/min720 × 1445 × 778PDF, 0.7 MBEnquire
MK 115115 lfrom −40 to +180 °C5.3 K/min5.0 K/min980 × 1725 × 865PDF, 0.8 MBEnquire
MK 240228 lfrom −40 to +180 °C5.0 K/min4.5 K/min1115 × 1710 × 925PDF, 1.0 MBEnquire
MK 400417 lfrom −40 to +180 °C5.0 K/min5.0 K/min1115 × 1710 × 1400PDF, 0.9 MBEnquire
MK 720734 lfrom −40 to +180 °C4.0 K/min4.5 K/min1580 × 2005 × 1140PDF, 0.9 MBEnquire
MK 1020991 lfrom −40 to +180 °C5.5 K/min5.0 K/min1580 × 2005 × 1480PDF, 0.9 MBEnquire

MK CO2 Temperature test chambers with CO2 refrigerant

The new generation of MK chambers, cooled with the natural refrigerant CO2 (R-744), from −48 to +180 °C (sizes 240 and 400: temporarily down to −50 °C). It cools from +180 to −40 °C in 60–⁠80 min (MK of the same size: 100–⁠120 min), and its high cooling capacity makes it possible to compensate for the heat given off by the samples.

MK CO2 models – technical data
ModelCapacityTemperature rangeHeating rate(average acc. to IEC 60068-3-5)Cooling rate(average acc. to IEC 60068-3-5)External dimensions(W × H × D, mm)Data sheetEnquiry
MK 240 CO2228 lfrom −50 to +180 °C5.5 K/min5.7 K/min1115 × 1710 × 925PDF, 0.7 MBEnquire
MK 400 CO2417 lfrom −50 to +180 °C5.7 K/min5.0 K/min1115 × 1710 × 1400PDF, 0.7 MBEnquire
MK 720 CO2734 lfrom −48 to +180 °C4.5 K/min5.7 K/min1580 × 2005 × 1140PDF, 0.8 MBEnquire
MK 1020 CO2991 lfrom −48 to +180 °C6.2 K/min4.8 K/min1580 × 2005 × 1480PDF, 0.7 MBEnquire

The MK 240 CO2 and MK 400 CO2 reach −50 °C only temporarily: according to BINDER, the temperature can be lowered to −50 °C for a maximum of 8 hours. In continuous operation, the range starts at −48 °C.

MKT Temperature test chambers down to −70 °C

Extended low-temperature range, from −70 to +180 °C, for cyclic temperature tests. Cooling is provided by a cascade refrigeration unit with R-452A and R-23 refrigerants.

MKT models – technical data
ModelCapacityTemperature rangeHeating rate(average acc. to IEC 60068-3-5)Cooling rate(average acc. to IEC 60068-3-5)External dimensions(W × H × D, mm)Data sheetEnquiry
MKT 115115 lfrom −70 to +180 °C5.3 K/min4.2 K/min980 × 1725 × 865PDF, 0.8 MBEnquire
MKT 240228 lfrom −70 to +180 °C5.0 K/min4.2 K/min1115 × 1935 × 925PDF, 0.7 MBEnquire
MKT 720734 lfrom −70 to +180 °C4.5 K/min4.0 K/min1580 × 2005 × 1140PDF, 0.9 MBEnquire

MKF Chambers with humidity control

For heat, cold and humidity tests according to DIN and IEC standards: from −40 to +180 °C and 10–⁠98 %. Steam humidification; sizes 240–⁠1020 have a built-in 20 l water tank.

MKF models – technical data
ModelCapacityTemperature rangeHeating rate(average acc. to IEC 60068-3-5)Cooling rate(average acc. to IEC 60068-3-5)External dimensions(W × H × D, mm)Data sheetEnquiry
MKF 5660 lfrom −40 to +180 °C5.0 K/min5.0 K/min720 × 1445 × 780PDF, 0.8 MBEnquire
MKF 240228 lfrom −40 to +180 °C5.0 K/min5.0 K/min1115 × 1715 × 925PDF, 1.2 MBEnquire
MKF 400417 lfrom −40 to +180 °C5.0 K/min5.0 K/min1115 × 1710 × 1400PDF, 1.0 MBEnquire
MKF 720734 lfrom −40 to +180 °C4.8 K/min4.8 K/min1580 × 2005 × 1140PDF, 1.1 MBEnquire
MKF 1020991 lfrom −40 to +180 °C5.5 K/min5.0 K/min1580 × 2005 × 1480PDF, 1.0 MBEnquire

MKF CO2 Chambers with humidity control and CO2 refrigerant

Combined tests of temperature from −48 to +180 °C (sizes 240 and 400: temporarily down to −50 °C) and humidity at 10–⁠98 %, with the natural refrigerant CO2 (R-744). It cools from +180 to −40 °C in 60–⁠80 min (MKF of the same size: 115–⁠120 min); 20 l water tank as standard.

MKF CO2 models – technical data
ModelCapacityTemperature rangeHeating rate(average acc. to IEC 60068-3-5)Cooling rate(average acc. to IEC 60068-3-5)External dimensions(W × H × D, mm)Data sheetEnquiry
MKF 240 CO2228 lfrom −50 to +180 °C5.5 K/min5.7 K/min1115 × 1713 × 925PDF, 0.9 MBEnquire
MKF 400 CO2417 lfrom −50 to +180 °C5.7 K/min5.0 K/min1115 × 1727 × 1400PDF, 0.9 MBEnquire
MKF 720 CO2734 lfrom −48 to +180 °C5.1 K/min5.7 K/min1580 × 2005 × 1140PDF, 0.9 MBEnquire
MKF 1020 CO2991 lfrom −48 to +180 °C6.2 K/min4.8 K/min1580 × 2005 × 1480PDF, 0.9 MBEnquire

The MKF 240 CO2 and MKF 400 CO2 reach −50 °C only temporarily: according to BINDER, the temperature can be lowered to −50 °C for a maximum of 8 hours. In continuous operation, the range starts at −48 °C.

MKFT Chambers with humidity control, down to −70 °C

For complex climate tests from −70 to +180 °C with humidity control at 10–⁠98 % (MKFT 115: 10–⁠95 %). Cascade refrigeration unit (R-452A and R-23), steam humidification and 20 l water tank.

MKFT models – technical data
ModelCapacityTemperature rangeHeating rate(average acc. to IEC 60068-3-5)Cooling rate(average acc. to IEC 60068-3-5)External dimensions(W × H × D, mm)Data sheetEnquiry
MKFT 115115 lfrom −70 to +180 °C5.5 K/min4.2 K/min980 × 1725 × 865PDF, 1.0 MBEnquire
MKFT 240228 lfrom −70 to +180 °C5.0 K/min4.2 K/min1115 × 1940 × 925PDF, 0.9 MBEnquire
MKFT 720734 lfrom −70 to +180 °C4.8 K/min4.0 K/min1580 × 2005 × 1140PDF, 1.1 MBEnquire

External dimensions as specified by BINDER: housing without accessories or connections.

See also: Battery test chambers with safety packages Custom solutions: UVA, UVB and sunlight simulation

Service, calibration and qualification

We are an authorised BINDER service provider. We look after equipment both under warranty and after the warranty has expired, calibrate it, measure temperature distribution according to DIN 12880 and carry out IQ/OQ qualification.

Contact

Sales office and service

SIMA
ul. Pokrzywnicka 3a
04-320 Warszawa

Show on map

Opening hours
24h/7

Write to us

Choose a topic and describe what you need. We will reply by email or phone.

What is your message about?

The data controller is „SIMA” s.c. P. Sikora, M. Gniadzik, ul. Pokrzywnicka 3a, 04-320 Warszawa. We will use the data from the form to reply to your message. More in our privacy policy.